German Dental FHIR Profiles (R4)
0.41.6 - trial-use
Germany
German Dental FHIR Profiles (R4) - Local Development build (v0.41.6) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Active as of 2026-07-29 |
<CodeSystem xmlns="http://hl7.org/fhir">
<id value="prosthetic-device-finding"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: CodeSystem prosthetic-device-finding</b></p><a name="prosthetic-device-finding"> </a><a name="hcprosthetic-device-finding"> </a><p>This case-sensitive code system <code>https://fhir.cognovis.de/dental/CodeSystem/prosthetic-device-finding</code> defines the following codes:</p><table class="codes"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td style="white-space:nowrap">base-fracture<a name="prosthetic-device-finding-base-fracture"> </a></td><td>Prosthesis base fracture</td><td>Fracture of a removable prosthesis base.</td></tr><tr><td style="white-space:nowrap">clasp-fracture<a name="prosthetic-device-finding-clasp-fracture"> </a></td><td>Clasp fracture</td><td>Fracture of a clasp on a removable prosthesis.</td></tr><tr><td style="white-space:nowrap">prosthetic-tooth-loss<a name="prosthetic-device-finding-prosthetic-tooth-loss"> </a></td><td>Loss of prosthetic tooth</td><td>Loss of a tooth from a removable prosthesis.</td></tr><tr><td style="white-space:nowrap">prosthetic-tooth-fracture<a name="prosthetic-device-finding-prosthetic-tooth-fracture"> </a></td><td>Fracture of prosthetic tooth</td><td>Fracture of a tooth on a removable prosthesis.</td></tr><tr><td style="white-space:nowrap">extension-required<a name="prosthetic-device-finding-extension-required"> </a></td><td>Prosthesis extension required</td><td>The removable prosthesis requires extension.</td></tr><tr><td style="white-space:nowrap">clasp-adjustment-required<a name="prosthetic-device-finding-clasp-adjustment-required"> </a></td><td>Clasp adjustment required</td><td>A clasp on the removable prosthesis requires adjustment.</td></tr><tr><td style="white-space:nowrap">localized-fit-loss<a name="prosthetic-device-finding-localized-fit-loss"> </a></td><td>Localized loss of fit</td><td>The removable prosthesis has a localized loss of fit.</td></tr><tr><td style="white-space:nowrap">generalized-fit-loss<a name="prosthetic-device-finding-generalized-fit-loss"> </a></td><td>Generalized loss of fit</td><td>The removable prosthesis has a generalized loss of fit.</td></tr><tr><td style="white-space:nowrap">screw-loosening<a name="prosthetic-device-finding-screw-loosening"> </a></td><td>Screw loosening</td><td>A screw in the implant suprastructure is loose.</td></tr><tr><td style="white-space:nowrap">screw-fracture<a name="prosthetic-device-finding-screw-fracture"> </a></td><td>Screw fracture</td><td>A screw in the implant suprastructure is fractured.</td></tr><tr><td style="white-space:nowrap">abutment-loosening<a name="prosthetic-device-finding-abutment-loosening"> </a></td><td>Abutment loosening</td><td>An abutment supporting the suprastructure is loose.</td></tr><tr><td style="white-space:nowrap">abutment-fracture<a name="prosthetic-device-finding-abutment-fracture"> </a></td><td>Abutment fracture</td><td>An abutment supporting the suprastructure is fractured.</td></tr><tr><td style="white-space:nowrap">crown-decementation<a name="prosthetic-device-finding-crown-decementation"> </a></td><td>Crown decementation</td><td>A crown belonging to the suprastructure has lost retention.</td></tr><tr><td style="white-space:nowrap">veneering-fracture<a name="prosthetic-device-finding-veneering-fracture"> </a></td><td>Veneering fracture</td><td>The veneering material of the suprastructure is fractured.</td></tr><tr><td style="white-space:nowrap">crown-fracture<a name="prosthetic-device-finding-crown-fracture"> </a></td><td>Crown fracture</td><td>A crown belonging to the suprastructure is fractured.</td></tr><tr><td style="white-space:nowrap">framework-fracture<a name="prosthetic-device-finding-framework-fracture"> </a></td><td>Framework fracture</td><td>The framework of the suprastructure is fractured.</td></tr><tr><td style="white-space:nowrap">attachment-retention-loss<a name="prosthetic-device-finding-attachment-retention-loss"> </a></td><td>Attachment retention loss</td><td>An attachment has lost retention.</td></tr><tr><td style="white-space:nowrap">attachment-wear<a name="prosthetic-device-finding-attachment-wear"> </a></td><td>Attachment wear</td><td>An attachment is worn.</td></tr><tr><td style="white-space:nowrap">matrix-wear<a name="prosthetic-device-finding-matrix-wear"> </a></td><td>Matrix wear</td><td>The matrix component of an attachment is worn.</td></tr></table></div>
</text>
<url
value="https://fhir.cognovis.de/dental/CodeSystem/prosthetic-device-finding"/>
<version value="0.41.6"/>
<name value="ProstheticDeviceFindingCS"/>
<title value="Prosthetic Device Finding"/>
<status value="active"/>
<experimental value="false"/>
<date value="2026-07-29T15:26:56+02:00"/>
<publisher value="cognovis GmbH"/>
<contact>
<name value="cognovis GmbH"/>
<telecom>
<system value="url"/>
<value value="https://www.cognovis.de"/>
</telecom>
<telecom>
<system value="email"/>
<value value="info@cognovis.de"/>
</telecom>
</contact>
<description
value="Manufacturer-neutral technical findings concerning removable dental prostheses and implant suprastructures."/>
<jurisdiction>
<coding>
<system value="urn:iso:std:iso:3166"/>
<code value="DE"/>
<display value="Germany"/>
</coding>
</jurisdiction>
<copyright
value="Copyright 2026+ cognovis GmbH. Licensed under CC-BY-4.0."/>
<caseSensitive value="true"/>
<content value="complete"/>
<count value="19"/>
<concept>
<code value="base-fracture"/>
<display value="Prosthesis base fracture"/>
<definition value="Fracture of a removable prosthesis base."/>
</concept>
<concept>
<code value="clasp-fracture"/>
<display value="Clasp fracture"/>
<definition value="Fracture of a clasp on a removable prosthesis."/>
</concept>
<concept>
<code value="prosthetic-tooth-loss"/>
<display value="Loss of prosthetic tooth"/>
<definition value="Loss of a tooth from a removable prosthesis."/>
</concept>
<concept>
<code value="prosthetic-tooth-fracture"/>
<display value="Fracture of prosthetic tooth"/>
<definition value="Fracture of a tooth on a removable prosthesis."/>
</concept>
<concept>
<code value="extension-required"/>
<display value="Prosthesis extension required"/>
<definition value="The removable prosthesis requires extension."/>
</concept>
<concept>
<code value="clasp-adjustment-required"/>
<display value="Clasp adjustment required"/>
<definition
value="A clasp on the removable prosthesis requires adjustment."/>
</concept>
<concept>
<code value="localized-fit-loss"/>
<display value="Localized loss of fit"/>
<definition
value="The removable prosthesis has a localized loss of fit."/>
</concept>
<concept>
<code value="generalized-fit-loss"/>
<display value="Generalized loss of fit"/>
<definition
value="The removable prosthesis has a generalized loss of fit."/>
</concept>
<concept>
<code value="screw-loosening"/>
<display value="Screw loosening"/>
<definition value="A screw in the implant suprastructure is loose."/>
</concept>
<concept>
<code value="screw-fracture"/>
<display value="Screw fracture"/>
<definition value="A screw in the implant suprastructure is fractured."/>
</concept>
<concept>
<code value="abutment-loosening"/>
<display value="Abutment loosening"/>
<definition value="An abutment supporting the suprastructure is loose."/>
</concept>
<concept>
<code value="abutment-fracture"/>
<display value="Abutment fracture"/>
<definition
value="An abutment supporting the suprastructure is fractured."/>
</concept>
<concept>
<code value="crown-decementation"/>
<display value="Crown decementation"/>
<definition
value="A crown belonging to the suprastructure has lost retention."/>
</concept>
<concept>
<code value="veneering-fracture"/>
<display value="Veneering fracture"/>
<definition
value="The veneering material of the suprastructure is fractured."/>
</concept>
<concept>
<code value="crown-fracture"/>
<display value="Crown fracture"/>
<definition
value="A crown belonging to the suprastructure is fractured."/>
</concept>
<concept>
<code value="framework-fracture"/>
<display value="Framework fracture"/>
<definition value="The framework of the suprastructure is fractured."/>
</concept>
<concept>
<code value="attachment-retention-loss"/>
<display value="Attachment retention loss"/>
<definition value="An attachment has lost retention."/>
</concept>
<concept>
<code value="attachment-wear"/>
<display value="Attachment wear"/>
<definition value="An attachment is worn."/>
</concept>
<concept>
<code value="matrix-wear"/>
<display value="Matrix wear"/>
<definition value="The matrix component of an attachment is worn."/>
</concept>
</CodeSystem>