"resourceType" : "CodeSystem",
"id" : "prosthetic-device-finding",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: CodeSystem prosthetic-device-finding</b></p><a name=\"prosthetic-device-finding\"> </a><a name=\"hcprosthetic-device-finding\"> </a><p>This case-sensitive code system <code>https://fhir.cognovis.de/dental/CodeSystem/prosthetic-device-finding</code> defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td style=\"white-space:nowrap\">base-fracture<a name=\"prosthetic-device-finding-base-fracture\"> </a></td><td>Prosthesis base fracture</td><td>Fracture of a removable prosthesis base.</td></tr><tr><td style=\"white-space:nowrap\">clasp-fracture<a name=\"prosthetic-device-finding-clasp-fracture\"> </a></td><td>Clasp fracture</td><td>Fracture of a clasp on a removable prosthesis.</td></tr><tr><td style=\"white-space:nowrap\">prosthetic-tooth-loss<a name=\"prosthetic-device-finding-prosthetic-tooth-loss\"> </a></td><td>Loss of prosthetic tooth</td><td>Loss of a tooth from a removable prosthesis.</td></tr><tr><td style=\"white-space:nowrap\">prosthetic-tooth-fracture<a name=\"prosthetic-device-finding-prosthetic-tooth-fracture\"> </a></td><td>Fracture of prosthetic tooth</td><td>Fracture of a tooth on a removable prosthesis.</td></tr><tr><td style=\"white-space:nowrap\">extension-required<a name=\"prosthetic-device-finding-extension-required\"> </a></td><td>Prosthesis extension required</td><td>The removable prosthesis requires extension.</td></tr><tr><td style=\"white-space:nowrap\">clasp-adjustment-required<a name=\"prosthetic-device-finding-clasp-adjustment-required\"> </a></td><td>Clasp adjustment required</td><td>A clasp on the removable prosthesis requires adjustment.</td></tr><tr><td style=\"white-space:nowrap\">localized-fit-loss<a name=\"prosthetic-device-finding-localized-fit-loss\"> </a></td><td>Localized loss of fit</td><td>The removable prosthesis has a localized loss of fit.</td></tr><tr><td style=\"white-space:nowrap\">generalized-fit-loss<a name=\"prosthetic-device-finding-generalized-fit-loss\"> </a></td><td>Generalized loss of fit</td><td>The removable prosthesis has a generalized loss of fit.</td></tr><tr><td style=\"white-space:nowrap\">screw-loosening<a name=\"prosthetic-device-finding-screw-loosening\"> </a></td><td>Screw loosening</td><td>A screw in the implant suprastructure is loose.</td></tr><tr><td style=\"white-space:nowrap\">screw-fracture<a name=\"prosthetic-device-finding-screw-fracture\"> </a></td><td>Screw fracture</td><td>A screw in the implant suprastructure is fractured.</td></tr><tr><td style=\"white-space:nowrap\">abutment-loosening<a name=\"prosthetic-device-finding-abutment-loosening\"> </a></td><td>Abutment loosening</td><td>An abutment supporting the suprastructure is loose.</td></tr><tr><td style=\"white-space:nowrap\">abutment-fracture<a name=\"prosthetic-device-finding-abutment-fracture\"> </a></td><td>Abutment fracture</td><td>An abutment supporting the suprastructure is fractured.</td></tr><tr><td style=\"white-space:nowrap\">crown-decementation<a name=\"prosthetic-device-finding-crown-decementation\"> </a></td><td>Crown decementation</td><td>A crown belonging to the suprastructure has lost retention.</td></tr><tr><td style=\"white-space:nowrap\">veneering-fracture<a name=\"prosthetic-device-finding-veneering-fracture\"> </a></td><td>Veneering fracture</td><td>The veneering material of the suprastructure is fractured.</td></tr><tr><td style=\"white-space:nowrap\">crown-fracture<a name=\"prosthetic-device-finding-crown-fracture\"> </a></td><td>Crown fracture</td><td>A crown belonging to the suprastructure is fractured.</td></tr><tr><td style=\"white-space:nowrap\">framework-fracture<a name=\"prosthetic-device-finding-framework-fracture\"> </a></td><td>Framework fracture</td><td>The framework of the suprastructure is fractured.</td></tr><tr><td style=\"white-space:nowrap\">attachment-retention-loss<a name=\"prosthetic-device-finding-attachment-retention-loss\"> </a></td><td>Attachment retention loss</td><td>An attachment has lost retention.</td></tr><tr><td style=\"white-space:nowrap\">attachment-wear<a name=\"prosthetic-device-finding-attachment-wear\"> </a></td><td>Attachment wear</td><td>An attachment is worn.</td></tr><tr><td style=\"white-space:nowrap\">matrix-wear<a name=\"prosthetic-device-finding-matrix-wear\"> </a></td><td>Matrix wear</td><td>The matrix component of an attachment is worn.</td></tr></table></div>"
},
"url" : "https://fhir.cognovis.de/dental/CodeSystem/prosthetic-device-finding",
"version" : "0.41.6",
"name" : "ProstheticDeviceFindingCS",
"title" : "Prosthetic Device Finding",
"status" : "active",
"experimental" : false,
"date" : "2026-07-29T15:26:56+02:00",
"publisher" : "cognovis GmbH",
"contact" : [
{
"name" : "cognovis GmbH",
"telecom" : [
{
"system" : "url",
"value" : "https://www.cognovis.de"
},
{
"system" : "email",
"value" : "info@cognovis.de"
}
]
}
],
"description" : "Manufacturer-neutral technical findings concerning removable dental prostheses and implant suprastructures.",
"jurisdiction" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "DE",
"display" : "Germany"
}
]
}
],
"copyright" : "Copyright 2026+ cognovis GmbH. Licensed under CC-BY-4.0.",
"caseSensitive" : true,
"content" : "complete",
"count" : 19,
"concept" : [
{
"code" : "base-fracture",
"display" : "Prosthesis base fracture",
"definition" : "Fracture of a removable prosthesis base."
},
{
"code" : "clasp-fracture",
"display" : "Clasp fracture",
"definition" : "Fracture of a clasp on a removable prosthesis."
},
{
"code" : "prosthetic-tooth-loss",
"display" : "Loss of prosthetic tooth",
"definition" : "Loss of a tooth from a removable prosthesis."
},
{
"code" : "prosthetic-tooth-fracture",
"display" : "Fracture of prosthetic tooth",
"definition" : "Fracture of a tooth on a removable prosthesis."
},
{
"code" : "extension-required",
"display" : "Prosthesis extension required",
"definition" : "The removable prosthesis requires extension."
},
{
"code" : "clasp-adjustment-required",
"display" : "Clasp adjustment required",
"definition" : "A clasp on the removable prosthesis requires adjustment."
},
{
"code" : "localized-fit-loss",
"display" : "Localized loss of fit",
"definition" : "The removable prosthesis has a localized loss of fit."
},
{
"code" : "generalized-fit-loss",
"display" : "Generalized loss of fit",
"definition" : "The removable prosthesis has a generalized loss of fit."
},
{
"code" : "screw-loosening",
"display" : "Screw loosening",
"definition" : "A screw in the implant suprastructure is loose."
},
{
"code" : "screw-fracture",
"display" : "Screw fracture",
"definition" : "A screw in the implant suprastructure is fractured."
},
{
"code" : "abutment-loosening",
"display" : "Abutment loosening",
"definition" : "An abutment supporting the suprastructure is loose."
},
{
"code" : "abutment-fracture",
"display" : "Abutment fracture",
"definition" : "An abutment supporting the suprastructure is fractured."
},
{
"code" : "crown-decementation",
"display" : "Crown decementation",
"definition" : "A crown belonging to the suprastructure has lost retention."
},
{
"code" : "veneering-fracture",
"display" : "Veneering fracture",
"definition" : "The veneering material of the suprastructure is fractured."
},
{
"code" : "crown-fracture",
"display" : "Crown fracture",
"definition" : "A crown belonging to the suprastructure is fractured."
},
{
"code" : "framework-fracture",
"display" : "Framework fracture",
"definition" : "The framework of the suprastructure is fractured."
},
{
"code" : "attachment-retention-loss",
"display" : "Attachment retention loss",
"definition" : "An attachment has lost retention."
},
{
"code" : "attachment-wear",
"display" : "Attachment wear",
"definition" : "An attachment is worn."
},
{
"code" : "matrix-wear",
"display" : "Matrix wear",
"definition" : "The matrix component of an attachment is worn."
}
]
}