Generated Narrative: CodeSystem prosthetic-device-finding

This case-sensitive code system https://fhir.cognovis.de/dental/CodeSystem/prosthetic-device-finding defines the following codes:

CodeDisplayDefinition
base-fracture Prosthesis base fractureFracture of a removable prosthesis base.
clasp-fracture Clasp fractureFracture of a clasp on a removable prosthesis.
prosthetic-tooth-loss Loss of prosthetic toothLoss of a tooth from a removable prosthesis.
prosthetic-tooth-fracture Fracture of prosthetic toothFracture of a tooth on a removable prosthesis.
extension-required Prosthesis extension requiredThe removable prosthesis requires extension.
clasp-adjustment-required Clasp adjustment requiredA clasp on the removable prosthesis requires adjustment.
localized-fit-loss Localized loss of fitThe removable prosthesis has a localized loss of fit.
generalized-fit-loss Generalized loss of fitThe removable prosthesis has a generalized loss of fit.
screw-loosening Screw looseningA screw in the implant suprastructure is loose.
screw-fracture Screw fractureA screw in the implant suprastructure is fractured.
abutment-loosening Abutment looseningAn abutment supporting the suprastructure is loose.
abutment-fracture Abutment fractureAn abutment supporting the suprastructure is fractured.
crown-decementation Crown decementationA crown belonging to the suprastructure has lost retention.
veneering-fracture Veneering fractureThe veneering material of the suprastructure is fractured.
crown-fracture Crown fractureA crown belonging to the suprastructure is fractured.
framework-fracture Framework fractureThe framework of the suprastructure is fractured.
attachment-retention-loss Attachment retention lossAn attachment has lost retention.
attachment-wear Attachment wearAn attachment is worn.
matrix-wear Matrix wearThe matrix component of an attachment is worn.
<status value="active"/> <experimental value="false"/> <date value="2026-07-29T15:26:56+02:00"/> <publisher value="cognovis GmbH"/> <contact> <name value="cognovis GmbH"/> <telecom> <system value="url"/> <value value="https://www.cognovis.de"/> </telecom> <telecom> <system value="email"/> <value value="info@cognovis.de"/> </telecom> </contact> <description value="Manufacturer-neutral technical findings concerning removable dental prostheses and implant suprastructures."/> <jurisdiction> <coding> <system value="urn:iso:std:iso:3166"/> <code value="DE"/> <display value="Germany"/> </coding> </jurisdiction> <copyright value="Copyright 2026+ cognovis GmbH. Licensed under CC-BY-4.0."/> <caseSensitive value="true"/> <content value="complete"/> <count value="19"/> <concept> <code value="base-fracture"/> <display value="Prosthesis base fracture"/> <definition value="Fracture of a removable prosthesis base."/> </concept> <concept> <code value="clasp-fracture"/> <display value="Clasp fracture"/> <definition value="Fracture of a clasp on a removable prosthesis."/> </concept> <concept> <code value="prosthetic-tooth-loss"/> <display value="Loss of prosthetic tooth"/> <definition value="Loss of a tooth from a removable prosthesis."/> </concept> <concept> <code value="prosthetic-tooth-fracture"/> <display value="Fracture of prosthetic tooth"/> <definition value="Fracture of a tooth on a removable prosthesis."/> </concept> <concept> <code value="extension-required"/> <display value="Prosthesis extension required"/> <definition value="The removable prosthesis requires extension."/> </concept> <concept> <code value="clasp-adjustment-required"/> <display value="Clasp adjustment required"/> <definition value="A clasp on the removable prosthesis requires adjustment."/> </concept> <concept> <code value="localized-fit-loss"/> <display value="Localized loss of fit"/> <definition value="The removable prosthesis has a localized loss of fit."/> </concept> <concept> <code value="generalized-fit-loss"/> <display value="Generalized loss of fit"/> <definition value="The removable prosthesis has a generalized loss of fit."/> </concept> <concept> <code value="screw-loosening"/> <display value="Screw loosening"/> <definition value="A screw in the implant suprastructure is loose."/> </concept> <concept> <code value="screw-fracture"/> <display value="Screw fracture"/> <definition value="A screw in the implant suprastructure is fractured."/> </concept> <concept> <code value="abutment-loosening"/> <display value="Abutment loosening"/> <definition value="An abutment supporting the suprastructure is loose."/> </concept> <concept> <code value="abutment-fracture"/> <display value="Abutment fracture"/> <definition value="An abutment supporting the suprastructure is fractured."/> </concept> <concept> <code value="crown-decementation"/> <display value="Crown decementation"/> <definition value="A crown belonging to the suprastructure has lost retention."/> </concept> <concept> <code value="veneering-fracture"/> <display value="Veneering fracture"/> <definition value="The veneering material of the suprastructure is fractured."/> </concept> <concept> <code value="crown-fracture"/> <display value="Crown fracture"/> <definition value="A crown belonging to the suprastructure is fractured."/> </concept> <concept> <code value="framework-fracture"/> <display value="Framework fracture"/> <definition value="The framework of the suprastructure is fractured."/> </concept> <concept> <code value="attachment-retention-loss"/> <display value="Attachment retention loss"/> <definition value="An attachment has lost retention."/> </concept> <concept> <code value="attachment-wear"/> <display value="Attachment wear"/> <definition value="An attachment is worn."/> </concept> <concept> <code value="matrix-wear"/> <display value="Matrix wear"/> <definition value="The matrix component of an attachment is worn."/> </concept> </CodeSystem>