German Practice Management FHIR Profiles (R4)
0.49.0 - STU1
German Practice Management FHIR Profiles (R4) - Local Development build (v0.49.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
<Procedure xmlns="http://hl7.org/fhir">
<id value="example-dvt-oberkiefer-implantat"/>
<meta>
<profile
value="https://fhir.cognovis.de/praxis/StructureDefinition/roentgen-procedure-praxis-de"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Procedure example-dvt-oberkiefer-implantat</b></p><a name="example-dvt-oberkiefer-implantat"> </a><a name="hcexample-dvt-oberkiefer-implantat"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-roentgen-procedure-praxis-de.html">Roentgen Procedure (Praxis DE)</a></p></div><blockquote><p><b>Radiation Dose</b></p><ul><li>dap: 1500 uGy.m2<span style="background: LightGoldenRodYellow"> (Details: UCUM codeuGy.m2 = 'uGy.m2')</span></li><li>kvp: 90 kV<span style="background: LightGoldenRodYellow"> (Details: UCUM codekV = 'kV')</span></li><li>exposureTime: 17 s<span style="background: LightGoldenRodYellow"> (Details: UCUM codes = 's')</span></li></ul></blockquote><p><b>status</b>: Completed</p><p><b>category</b>: <span title="Codes:{http://snomed.info/sct 103693007}">Diagnostic procedure</span></p><p><b>code</b>: <span title="Codes:{http://snomed.info/sct 1255414003}">Cone beam computed tomography of maxilla</span></p><p><b>subject</b>: <a href="Patient-example-patient-dvt.html">Max Hartmann (official) Male, DoB: 1978-09-12</a></p><p><b>performed</b>: 2026-04-30 10:30:00+0200</p><blockquote><p><b>performer</b></p><p><b>Anwender Fachkunde Strahlenschutz</b>: <a href="https://simplifier.net/resolve?scope=de.cognovis.terminology.imaging@2026.0.0&canonical=https://fhir.cognovis.de/imaging/CodeSystem/fachkunde-strahlenschutz#fachkunde-strahlenschutz-dvt">Fachkunde Strahlenschutz: dvt</a> (Fachkunde DVT)</p><p><b>function</b>: <span title="Codes:{https://fhir.cognovis.de/praxis/CodeSystem/radiology-role MTR}">MTR</span></p><p><b>actor</b>: <a href="Practitioner-example-practitioner-mtr-dvt.html">Practitioner Klaus Richter (official)</a></p></blockquote><blockquote><p><b>performer</b></p><p><b>function</b>: <span title="Codes:{https://fhir.cognovis.de/praxis/CodeSystem/radiology-role SupervisingRadiologist}">Supervising Radiologist</span></p><p><b>actor</b>: <a href="Practitioner-example-practitioner-radiologin-dvt.html">Practitioner Anna Hofmann (official)</a></p></blockquote><p><b>reasonCode</b>: <span title="Codes:{http://fhir.de/CodeSystem/bfarm/icd-10-gm K08.1}">Implantatplanung Region 16 nach Extraktion — DVT fuer 3D-Knochenvolumen-Analyse</span></p></div>
</text>
<extension
url="https://fhir.cognovis.de/praxis/StructureDefinition/radiation-dose">
<extension url="dap">
<valueQuantity>
<value value="1500"/>
<unit value="uGy.m2"/>
<system value="http://unitsofmeasure.org"/>
<code value="uGy.m2"/>
</valueQuantity>
</extension>
<extension url="kvp">
<valueQuantity>
<value value="90"/>
<unit value="kV"/>
<system value="http://unitsofmeasure.org"/>
<code value="kV"/>
</valueQuantity>
</extension>
<extension url="exposureTime">
<valueQuantity>
<value value="17"/>
<unit value="s"/>
<system value="http://unitsofmeasure.org"/>
<code value="s"/>
</valueQuantity>
</extension>
</extension>
<status value="completed"/>
<category>
<coding>
<system value="http://snomed.info/sct"/>
<code value="103693007"/>
<display value="Diagnostic procedure"/>
</coding>
</category>
<code>
<coding>
<system value="http://snomed.info/sct"/>
<code value="1255414003"/>
<display value="Cone beam computed tomography of maxilla"/>
</coding>
</code>
<subject>🔗
<reference value="Patient/example-patient-dvt"/>
</subject>
<performedDateTime value="2026-04-30T10:30:00+02:00"/>
<performer>
<extension
url="https://fhir.cognovis.de/praxis/StructureDefinition/anwender-fachkunde">
<valueCoding>
<system
value="https://fhir.cognovis.de/imaging/CodeSystem/fachkunde-strahlenschutz"/>
<code value="dvt"/>
<display value="Fachkunde DVT"/>
</valueCoding>
</extension>
<function>
<coding>
<system
value="https://fhir.cognovis.de/praxis/CodeSystem/radiology-role"/>
<code value="MTR"/>
<display value="MTR"/>
</coding>
</function>
<actor>🔗
<reference value="Practitioner/example-practitioner-mtr-dvt"/>
</actor>
</performer>
<performer>
<function>
<coding>
<system
value="https://fhir.cognovis.de/praxis/CodeSystem/radiology-role"/>
<code value="SupervisingRadiologist"/>
<display value="Supervising Radiologist"/>
</coding>
</function>
<actor>🔗
<reference value="Practitioner/example-practitioner-radiologin-dvt"/>
</actor>
</performer>
<reasonCode>
<extension
url="https://fhir.cognovis.de/praxis/StructureDefinition/rechtfertigende-indikation-attest">
<extension url="assessor">
<valueReference>🔗
<reference
value="Practitioner/example-practitioner-radiologin-dvt"/>
</valueReference>
</extension>
<extension url="assessmentDate">
<valueDateTime value="2026-04-30T09:45:00+02:00"/>
</extension>
<extension url="narrative">
<valueString
value="Implantatplanung Region 16 — DVT indiziert fuer exakte Knochenhoehen- und -breitenbestimmung sowie Nachweis ausreichender Knochensubstanz fuer Implantat. Keine konventionelle Roentgenalternative ausreichend."/>
</extension>
</extension>
<coding>
<system value="http://fhir.de/CodeSystem/bfarm/icd-10-gm"/>
<code value="K08.1"/>
<display
value="Verlust von Zaehnen durch Unfall, Extraktion oder lokale parodontale Erkrankung"/>
</coding>
<text
value="Implantatplanung Region 16 nach Extraktion — DVT fuer 3D-Knochenvolumen-Analyse"/>
</reasonCode>
</Procedure>