German Dental FHIR Profiles (R4)
0.41.6 - trial-use Germany

German Dental FHIR Profiles (R4) - Local Development build (v0.41.6) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: Implant Suprastructure Finding - XML Representation

Active as of 2026-07-29

Raw xml | Download


<ValueSet xmlns="http://hl7.org/fhir">
  <id value="suprastructure-finding"/>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ValueSet suprastructure-finding</b></p><a name="suprastructure-finding"> </a><a name="hcsuprastructure-finding"> </a><ul><li>Include these codes as defined in <a href="CodeSystem-prosthetic-device-finding.html"><code>https://fhir.cognovis.de/dental/CodeSystem/prosthetic-device-finding</code></a><span title="Version is not explicitly stated, which means it is fixed to the version provided in this specification"> version &#x1F4E6;0.41.6</span><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-screw-loosening">screw-loosening</a></td><td style="color: #cccccc">Screw loosening</td><td>A screw in the implant suprastructure is loose.</td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-screw-fracture">screw-fracture</a></td><td style="color: #cccccc">Screw fracture</td><td>A screw in the implant suprastructure is fractured.</td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-abutment-loosening">abutment-loosening</a></td><td style="color: #cccccc">Abutment loosening</td><td>An abutment supporting the suprastructure is loose.</td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-abutment-fracture">abutment-fracture</a></td><td style="color: #cccccc">Abutment fracture</td><td>An abutment supporting the suprastructure is fractured.</td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-crown-decementation">crown-decementation</a></td><td style="color: #cccccc">Crown decementation</td><td>A crown belonging to the suprastructure has lost retention.</td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-veneering-fracture">veneering-fracture</a></td><td style="color: #cccccc">Veneering fracture</td><td>The veneering material of the suprastructure is fractured.</td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-crown-fracture">crown-fracture</a></td><td style="color: #cccccc">Crown fracture</td><td>A crown belonging to the suprastructure is fractured.</td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-framework-fracture">framework-fracture</a></td><td style="color: #cccccc">Framework fracture</td><td>The framework of the suprastructure is fractured.</td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-attachment-retention-loss">attachment-retention-loss</a></td><td style="color: #cccccc">Attachment retention loss</td><td>An attachment has lost retention.</td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-attachment-wear">attachment-wear</a></td><td style="color: #cccccc">Attachment wear</td><td>An attachment is worn.</td></tr><tr><td><a href="CodeSystem-prosthetic-device-finding.html#prosthetic-device-finding-matrix-wear">matrix-wear</a></td><td style="color: #cccccc">Matrix wear</td><td>The matrix component of an attachment is worn.</td></tr></table></li></ul></div>
  </text>
  <url
       value="https://fhir.cognovis.de/dental/ValueSet/suprastructure-finding"/>
  <version value="0.41.6"/>
  <name value="SuprastructureFindingVS"/>
  <title value="Implant Suprastructure Finding"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2026-07-29T15:26:56+02:00"/>
  <publisher value="cognovis GmbH"/>
  <contact>
    <name value="cognovis GmbH"/>
    <telecom>
      <system value="url"/>
      <value value="https://www.cognovis.de"/>
    </telecom>
    <telecom>
      <system value="email"/>
      <value value="info@cognovis.de"/>
    </telecom>
  </contact>
  <description
               value="Technical findings concerning an implant-supported suprastructure."/>
  <jurisdiction>
    <coding>
      <system value="urn:iso:std:iso:3166"/>
      <code value="DE"/>
      <display value="Germany"/>
    </coding>
  </jurisdiction>
  <copyright
             value="Copyright 2026+ cognovis GmbH. Licensed under CC-BY-4.0."/>
  <compose>
    <include>
      <system
              value="https://fhir.cognovis.de/dental/CodeSystem/prosthetic-device-finding"/>
      <concept>
        <code value="screw-loosening"/>
      </concept>
      <concept>
        <code value="screw-fracture"/>
      </concept>
      <concept>
        <code value="abutment-loosening"/>
      </concept>
      <concept>
        <code value="abutment-fracture"/>
      </concept>
      <concept>
        <code value="crown-decementation"/>
      </concept>
      <concept>
        <code value="veneering-fracture"/>
      </concept>
      <concept>
        <code value="crown-fracture"/>
      </concept>
      <concept>
        <code value="framework-fracture"/>
      </concept>
      <concept>
        <code value="attachment-retention-loss"/>
      </concept>
      <concept>
        <code value="attachment-wear"/>
      </concept>
      <concept>
        <code value="matrix-wear"/>
      </concept>
    </include>
  </compose>
</ValueSet>